Incremental encoder IV5800

Robust optical standard rotary encoder, solid shaft

Profile IV5800:

  • Resolution max. 5000 pulses/revolution
  • IP65 or IP66/IP67 protection class
  • Robust bearing construction
  • -40 … 85° C operating temperature
  • High shock and vibration resistance
UL listing marks for Canada and the United States

Inquire about product/Add to leaflet
Mechanical data
FeatureTechnical dataAdditional information
Shaftstainless steel
Housingdie-cast
Speed≤12000 rpm IP65
≤6000 rpm IP65 continuous operation
≤6000 rpm IP66/IP67
≤3000 rpm IP66/IP67 continuous operation
Moment of inertia~1.8 x 10-6 kgm2
Starting torque<0.01 Nm at 20 °C IP65
<0.05 Nm at 20 °C IP66/IP67
Shaft load rating100 N radial
50 N axial
Cable sheathPVC ∼ø6.7 mm
Cable bending radius75 mm static
110 mm dynamic
Weight~0.4 kg
Table of dimensions
Measure ød [mm]Measure L [mm]
6h7 10
8h7 15
10h7 20
Electrical data
PP output circuit
FeatureTechnical dataAdditional information
Operating voltage10 … 30 V DC reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumptiontypical 50 mA ≤100 mA (no load)
Output signal level high≥UB - 1.0 V short-circuit proof
Output signal level low≤0.5 V short-circuit proof
Pulse frequency≤300 kHz
Load±20 mA max. adm.
Type of connection1x M12 connector 5-pole, 1x pin
OP output circuit
FeatureTechnical dataAdditional information
Operating voltage10 … 30 V DC reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumptiontypical 50 mA ≤100 mA (no load)
Output signal level high≥UB - 1.0 V short-circuit proof
Output signal level low≤0.5 V short-circuit proof
Pulse frequency≤300 kHz
Load±20 mA max. adm.
Type of connectionopen cable end
1x M23 connector 12-pole, 1x pin
LD output circuit
FeatureTechnical dataAdditional information
Operating voltage5 … 30 V DC reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumptiontypical 40 mA ≤90 mA (no load)
Output signal level high≥2.5 V short-circuit proof, not against UB
Output signal level low≤0.5 V short-circuit proof, not against UB
Pulse frequency≤300 kHz
Load±20 mA max. adm.
Type of connectionopen cable end
1x M23 connector 12-pole, 1x pin
signal pattern
System data
FeatureTechnical dataAdditional information
ApprovalUL UL 61010-1, File No. E503367
Characteristics of functional safety
FeatureTechnical dataAdditional information
MTTFd60.1 year(s)
Ambient conditions
FeatureTechnical dataAdditional information
Ambient temperature-40 … 85 °C plug
-30 … 85 °C static laying of cables
-20 … 85 °C dynamic laying of cables
EMCEN 61326-1 immunity requirement of industry
Safety regulationsUL 61010-1 Indoor use, outdoor use possible, not intended for use involving direct exposure to UV light.
Environment dry / wet.
Protection class III as per EN 61140.
Pollution degree 2 as per EN 61010.
Maximum humidity 93% at 40 °C.
Protection categoryIP65, IP66/IP67 EN 60529 (protection type not yet reviewed by UL)
Shock resistance3000 m/s2, 6 ms EN 60068-2-27
Vibration resistance300 m/s2, 10 … 2000 Hz EN 60068-2-6
Incremental encoder IV5800
Pin assignment
LD, PP, OP output circuits
Signal OP, LDSignal PPCable color E1
/Bncpink
+SUB (sense line)+SUB (sense line)red-blue
00blue
/0ncred
AAgreen
/Ancyellow
BBgray
GNDGNDwhite
SGND (sense line)SGND (sense line)gray-pink
+UB+UBbrown
PP output circuit
SignalPIN E12
GND1
+UB2
A3
B4
05
LD, OP output circuits
SignalPIN E2
/B 1
+SUB (Sense line) 2
0 3
/0 4
A 5
/A 6
nc 7
B 8
nc 9
GND 10
SGND (Sense line) 11
+UB 12
Scope of delivery
  • IV5800
  • Quick Start Guide
Ordering table
Feature Order data Specifications Additional information
Pulses/revolution
A...
50, 64, 100, 200, 250, 256, 300, 360, 400, 500, 512, 800, 1000, 1024, 1200, 2000, 2048, 2500, 3600, 4000, 600, 4096, 5000
 
Type of connection
BE1
open cable endonly with OP, LD
E2
plug M23only with OP, LD
E12
plug M12only with PP
 
Position of electrical connection
CA
axial
R
radial
 
Cable length
D...
01.0, 02.0, 03.0, 04.0, 05.0, 06.0, 08.0, 10.0, 15.0, 20.0 in monly with E1
OK
only with E2 and E12
 
Mounting type
EM1
clamping flange
M2
servo flange
 
Output circuit
FPP
push-pull
OP
push-pull with inversion
LD
LineDriver
 
Shaft diameter x length
G6x10
ø6 mm, length 10 mm
8x15
ø8 mm, length 15 mm
10x20
ø10 mm, length 20 mm
 
Protection category
HIP65
IP65
IP66/67
IP66/IP67
 
Ordering key
IV5800
-
AB0
-
A
-
B
-
C
-
D
-
E
-
F
-
G
-
H