Setpoint display AP10T

with bus interface, for format part or tool change

open expert video
Setpoint display with communication interface visualizes instructions for the operator during product change or format changes. Readability is optimized for intuitive user prompting: The red/green LEDs indicate whether a format part change is required. With the help of the backlit display, designations or setpoint and actual value can be clearly displayed. The operator confirms the changeover using an acknowledgment button.
This means that faulty machine settings with the setpoint display AP10T can be avoided in the future, making flexible production machines more process-reliable.

Profile AP10T:

  • Setpoint display with bus interface without measurement of actual value
  • Large control key to confirm target value
  • Optimally readable backlit display
  • Two-line LCD-Display
  • Integrated RS485 interface, CAN bus as an option
  • User guidance via bicolor status LEDs
  • IP53 protection class, IP65 as an option
CANopen SIKONETZ5 UL Recognized Component Marks for Canada and the United States

Inquire about product/Add to leaflet
Mechanical data
FeatureTechnical dataAdditional information
Housingreinforced plastic plug thread, nickel-plated brass/cover, metal ground connection
Color

black, RAL 9005

Weight~0.09 kg
Electrical data
FeatureTechnical dataAdditional information
Operating voltage24 V DC ±20 %
Current consumption~30 mA

additional ~3 mA per LED when operated with LEDs

Power input~0.72 VA Max. power supply of the power supply unit used: 100 VA.
The power supply used corresponds to SELV/Limited Energy (IEC 61010-1) or SELV/LPS (IEC 60950-1) or Class 2 (UL 1310).
Parameter storage105 cycles also applies to calibration operations
Display/display range

6-digit LCD 14-segment, ~8 mm height

decimal points, 2 rows, (backlit LED red/white)

Status display

2x two-color LED (red/green)

acknowledgment status, configurable

Keys

acknowledgment, parameterization

Bus connectionRS485; CANopen

no galvanic isolation

Type of connection

2x M8-plug connectors (A-coded)

4-pole, 1x socket, 1x pin

grounding via flat male tab 6.3 mm or terminal lug

System data
FeatureTechnical dataAdditional information
ApprovalUL UL 61010-1, File No. E503367
Ambient conditions
FeatureTechnical dataAdditional information
Ambient temperature0 … 60 °C
Storage temperature-20 … 80 °C
Relative humidity condensation inadmissible
EMCEN 61326-1 Industry immunity requirement, class B emission limit, shielded line required
Safety regulationsDIN EN 61010-1 (VDE 0411-1), UL 61010-1 Limited power supply according to DIN EN 61010-1 Section 9.4.
Protection class II
Surge category II
Pollution level 2
Protection categoryIP53

EN 60529, only with mating connector (protection class not examined by UL)

IP65

EN 60529, only with mating connector (protection class not examined by UL)

Shock resistance500 m/s2, 11 ms

EN 60068-2-27

Vibration resistance100 m/s2, 5 … 150 Hz

EN 60068-2-6

Setpoint display AP10T
Pin assignment
Interfaces
RS485CAN busPIN
TxRx-/DÜBCANL1
TxRx+/DÜACANH2
+24 V DC+24 V DC3
GNDGND4
Scope of delivery
  • AP10T
  • Mounting instructions
  • Documentation on CD
Ordering table
Feature Order data Specifications Additional information
Interface/protocol
AS3/09
RS485/SIKONETZ5
CAN
CANopen
 
Protection category
BIP53
IP53
IP65
IP65
 
Viewing window
CSF
front foil
K
plasticimpact protection
 
Ordering key
AP10T
-
A
-
B
-
EX
-
C
-
S
additional accessoriesOrdering key
Mating connector, 4-pole, socket84209
Mating connector,

4-pole, pin

84210
Bus terminating connector,

4-pole, pin

BAS-0005