Magnetic sensor MSC500
Compact sensor, incremental, digital interface, resolution 1 μm
The MSC500 magnetic sensor has a large, multi-color status LED that makes commissioning and function monitoring easier for users.The correct distance between the gage and the sensor can be visually monitored.With the plug connection directly on the sensor head, the MSC500 is also suitable for use in very confined spaces. As a result installation is fast and simple, which naturally means lower costs.In addition, the MSC500 sensor includes all digital square wave signals. This enables evaluation of the A/B signals, the inverted signals and the periodic index signals with the same sensor.
- max. resolution 1 μm
- max. 200000 pulses/revolution in conjunction with MR500 or MBR500 (160 poles)
- Repeat accuracy ±0.005 mm
- Status LED with integrated distance monitoring
- Works with magnetic tape MB500/1, magnetic ring MR500, magnetic band ring MBR500
- Reading distance ≤2 mm
- Sensor connection can be plugged with KV1C cable extension
- Output circuit PP, TTL, LD (depending on the operating voltage)
- optionally with reference point R or flexible reference marks FR
Technical drawing
Technical Specifications
Mechanical data
Electrical data
System data
Ambient conditions
Feature
Technical Specifications
Enhancement
Housing
 black plastic
Sensor/band reading distance
0.1 … 2 mm
I reference signals
0.1 … 1.5 mm
R reference signal
0.4 … 1 mm
FR reference signal
Sensor/ring reading distance
0.1 … 2 mm
I reference signals
0.1 … 1.5 mm
R reference signal
Travel/circumferential speed
Travel/circumferential speed Vmax [m/s] |
|||||||||||
Resolution/ Scaling factor |
0.001/1250 |
4.00 |
3.20 |
1.60 |
0.80 |
0.32 |
0.20 |
0.10 |
0.05 |
0.03 |
0.01 |
0.005/250 |
20.00 |
16.00 |
8.00 |
4.00 |
1.60 |
1.00 |
0.50 |
0.25 |
0.13 |
0.06 |
|
0.01/125 |
25.00 |
25.00 |
16.00 |
8.00 |
3.20 |
2.00 |
1.00 |
0.50 |
0.25 |
0.12 |
|
0.025/50 |
25.00 |
25.00 |
25.00 |
20.00 |
8.00 |
5.00 |
2.50 |
1.25 |
0.63 |
0.30 |
|
0.05/25 |
25.00 |
25.00 |
25.00 |
25.00 |
16.00 |
10.00 |
5.00 |
2.50 |
1.25 |
0.61 |
|
0.1/12.5 |
25.00 |
25.00 |
25.00 |
25.00 |
25.00 |
20.00 |
10.00 |
5.00 |
2.50 |
1.21 |
|
Pulse interval [μs] |
0.20 |
0.25 |
0.50 |
1.00 |
2.50 |
4.00 |
8.00 |
16.00 |
32.00 |
66.00 |
|
Counting frequency [kHz] |
1250.00 |
1000.00 |
500.00 |
250.00 |
100.00 |
62.50 |
31.25 |
15.63 |
7.81 |
3.79 |
|
3 |
2 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
Feature
Technical Specifications
Enhancement
Operating voltage
4.75 … 30 V DC
reverse polarity protection
Current consumption
<30
 mA
 at 24 V DC
unloaded
<75
 mA
 at 24 V DC
loaded
Output circuit
 PP
with operating voltage 4.75 … 30 V DC
 TTL, LD (RS422)
with operating voltage 4.75 … 6 V DC
Output signals
A, /A, B, /B, I, /I, R, /R, FR, /FR
Output signal level high
>UB -2.5 V
PP
>2.5
 V
LD
Output signal level low
0.8
 V
Latency
1.5
 µs
Index marks
 periodic, fixed, flexible
Pulse width of reference signal
1 or 4 increment(s)
Real-time requirement
 speed-proportional signal output
Type of connection
 plug connector
8-pole, 1x pin
Signal image
Note
The logical condition of signals A and B is not defined in reference to the index signal I or the reference signal R. It can deviate from the signal form.
Pulse interval, LD output circuit
Feature
Technical Specifications
Enhancement
Pole length
5
 mm
Resolution
0.001
 mm
,
0.005
,
0.01
,
0.025
,
0.05
,
0.1
 mm
Scaling factor
12.5
 
,
25
,
50
,
125
,
250
,
1250
 
System accuracy
 ±(0.025 + 0.01 x L) mm, L in m
±0.1
 °
Repeat accuracy
±5
 µm
Measuring range
∞
Circumferential speed
 Dependent on resolution and pulse interval
see table
Travel speed
 Dependent on resolution and pulse interval
see table
Feature
Technical Specifications
Enhancement
Ambient temperature
-40 … 85 °C
Storage temperature
-40 … 85 °C
Relative humidity
100
 %
condensation admissible
EMC
 EN 61326-1
immunity requirement of industrial applications, emission limit class B
Protection category
 IP67
EN 60529, mating connector mounted
Shock resistance
≤500 m/s2, 11 ms
EN 60068-2-27, half-sine, 3 axes (+/-), each 3 shocks
Vibration resistance
≤100 m/s2, 10 Hz … 2000 Hz
EN 60068-2-6, 3 axes, each 10 cycles
More information
pin assignment
in conjunction with cable extension KV1C
Signal |
4-core |
5-core |
6-core |
8-core |
A |
red |
red |
red |
red |
B |
orange |
orange |
orange |
orange |
I, R, FR |
blue |
blue |
||
+UB |
brown |
brown |
brown |
brown |
GND |
black |
black |
black |
black |
/A |
yellow |
yellow |
||
/B |
green |
green |
||
/I, /R, /FR |
violet |
Hint for mounting
For systems with reference points on the magnetic tape please take care that sensor and strip are correctly aligned (see picture).
Reference signal |
I |
R |
FR |
A, Sensor/tape reading distance |
≤2 mm |
≤1.5 mm |
0.4 … 1 mm |
B, Lateral offset |
±2 mm |
±0.5 mm |
±0.5 mm |
C, Alignment error |
±3° |
±3° |
±3° |
D, Longitudinal inclination |
±1° |
±1° |
±1° |
E, Lateral inclination |
±3° |
±3° |
±3° |
3 |
2 |
2 |
2 |
Symbolic representation
(Sensor representation symbolic)
Purchase order
Product configuration
Feature
Select specifications
Enhancement
Select your specifications:
reference signal
I
linear resolution/
radial scaling factor
0.001/1250
Pulse interval
0.2
Accessories
Scope of delivery
- MSC500
- Fastening set