Magnetic sensor MSK210
Incremental, digital interface, resolution 25 μm
- Max. resolution 25 μm
- max. resolution 0.045° with MR200 or MBR200 (100 poles)
- Repeat accuracy ±0.025 mm
- Repeat accuracy ±1 increment
- Works with magnetic tape MB200/1
- Works with MR200 magnetic ring, MBR200 magnetic tape ring
- Reading distance ≤1 mm
- Reading distance ≤0.8 mm
- Max. 4600 pulses/revolution with MBR200 (230 poles)
Technical drawing
Technical Specifications
Mechanical data
Electrical data
System data
Ambient conditions
Feature
Technical Specifications
Enhancement
Housing
 green plastic
Sensor/band reading distance
0.1 … 1 mm
O, I reference signals
0.1 … 0.4 mm
R reference signal
Sensor/ring reading distance
0.1 … 0.8 mm
O, I reference signals
0.1 … 0.4 mm
R reference signal
Cable sheath
 PUR, suitable for drag-chain use
4-core ø 4.4-0.4 mm; 5, 6, 8-core ø 5-0.4 mm
Cable bending radius
 5x cable diameter
static
 7.5x cable diameter
dynamic
Service life of cable
>5
 Million cycles
Under the following test conditions:
Feature
Technical Specifications
Enhancement
Operating voltage
24 V DC ±20 %
reverse polarity protection
5 V DC ±5 %
no reverse polarity protection
Current consumption
<20
 mA
 at 24 V DC
unloaded
<75
 mA
loaded
Output circuit
 PP, LD (RS422), TTL
PP only at 24 V
Output signals
A, /A, B, /B, I, /I, R, /R
quadrature signal
Output signal level high
>UB -2.5 V
PP
>2.5
 V
LD
>2.4
 V
TTL
Output signal level low
<0.8
 V
PP
<0.5
 V
LD
<0.4
 V
TTL
Latency
1.5
 µs
Jitter
<15
 %
0.5 mm reading distance
Pulse width of reference signal
1
 Increment(s)
Real-time requirement
 speed-proportional signal output
Type of connection
 open cable end
 plug connector
7/8-pole
 D-SUB
9-pole
Signal image
Note
The logical condition of signals A and B is not defined in reference to the index signal I or the reference signal R. It can deviate from the signal form.
Feature
Technical Specifications
Enhancement
Resolution
0.025
 mm
,
0.05
,
0.1
,
0.5
 mm
Scaling factor
1
 
,
5
,
10
,
20
System accuracy
±(0.05 + 0.01 x L) mm, L in m
 at TU = 20° C
±0.1
 °
 at TU = 20° C
Repeat accuracy
±1
 Increment(s)
Measuring range
∞
Circumferential speed
≤25
 m/s
≤2 m/s referencing speed
Travel speed
≤25
 m/s
≤2 m/s referencing speed
Feature
Technical Specifications
Enhancement
Ambient temperature
-10 … 70 °C
Storage temperature
-30 … 80 °C
Relative humidity
100
 %
condensation admissible
EMC
 EN 61000-6-2
interference resistance / immission
 EN 61000-6-4
emitted interference / emission
Protection category
 IP67
EN 60529
Shock resistance
500 m/s2, 11 ms
EN 60068-2-27
Vibration resistance
<100 m/s2, 5 … 150 Hz
EN 60068-2-6
More information
pin assignment
Not inverted with reference signal
Signal |
E1 |
E6X |
E8X |
GND |
black |
1 |
1 |
+UB |
brown |
2 |
2 |
A |
red |
3 |
3 |
B |
orange |
4 |
4 |
I, R |
blue |
5 |
5 |
nc |
6 |
6 |
|
nc |
7 |
7 |
|
nc |
8 |
||
nc |
9 |
Inverted with reference signal
Signal |
E1 |
E6X |
E8X |
A |
red |
1 |
1 |
B |
orange |
2 |
2 |
I, R |
blue |
3 |
3 |
+UB |
brown |
4 |
4 |
GND |
black |
5 |
5 |
A/ |
yellow |
6 |
6 |
B/ |
green |
7 |
7 |
I/, R/ |
violet |
8 |
8 |
nc |
9 |
Inverted without reference signal
Signal |
E1 |
E6X |
E8X |
A |
red |
1 |
1 |
B |
orange |
2 |
2 |
nc |
3 |
3 |
|
+UB |
brown |
4 |
4 |
GND |
black |
5 |
5 |
A/ |
yellow |
6 |
6 |
B/ |
green |
7 |
7 |
nc |
8 |
||
nc |
9 |
Hint for mounting
For systems with reference points on the magnetic tape please take care that sensor and strip are correctly aligned (see picture).
Reference signal |
O, I linear |
O, I radial |
R |
A, Sensor/tape reading distance |
≤1 mm |
≤0.8 mm |
≤0.4 mm |
B, Lateral offset |
±2 mm |
±2 mm |
±0.5 mm |
C, Alignment error |
±1° |
±1° |
±1° |
D, Longitudinal inclination |
±1° |
±1° |
±1° |
E, Lateral inclination |
±3° |
±3° |
±3° |
4 |
2 |
2 |
2 |
(Sensor representation symbolic)
(Sensor representation symbolic)
Purchase order
Product configuration
Feature
Select specifications
Enhancement
Select your specifications:
Operating voltage
4
A voltage drop is to be expected with increasing cable length. This must be taken into account in the electrical design.
Type of connection
E1
Cable length
02.0
02.0
20 m, in intervals of 1 m
Output circuit
PP
only with operating voltage 4
only with non-inverted output signal, cable length ≤5 m
output signal
NI
reference signal
O
index signal every 2 mm
linear resolution/
radial scaling factor
0.025/20
Scope of delivery
- MSK210
- Fastening set
- Installation Instructions