Measurement display MA501
Quasi-absolute, multi-line LCD dot matrix display
- Display accuracy max. 10 μm
- Repeat accuracy max. ±0.01 mm
- freely programmable high-resolution LCD dot matrix display
- Battery-buffered memory
- hard-wired sensor
- Option: serial RS485 interface
Technical drawing
Technical Specifications
Mechanical data
Electrical data
System data
Ambient conditions
Feature
Technical Specifications
Enhancement
Weight
~0.07
 kg
Housing design
 built-in housing, plastic (transparent)
Control panel excerpt 93+0.8 x 45+0.6 IEC 61554
Sensor/band reading distance
≤2
 mm
Cable sheath
 PVC
4-core ø3.15 -0.3 mm (data/network)
 PVC
6-core ø3.55 -0.3 mm (sensor)
Feature
Technical Specifications
Enhancement
Operating voltage
24 V DC ±20 %
 (10 … 30 V)
reverse polarity protection
1.5 V DC (1.2 … 1.6 V)
backup
Current consumption
-8
 mA
active at 24 V DC
<0.1
 mA
at 1.5 V DC active measuring system, display switched off
Display/display range
 2-row, DOT matrix
-999999 … 999999
Status display
 two-color backlit LCD display (green/red)
only with SW03 software
Interface
 RS485 (LAN interface)
Type of connection
 cable led outward
supply
Feature
Technical Specifications
Enhancement
Resolution
≤10
 µm
System accuracy
±(0.1 + 0.01 x L) mm, L in m
 at TU = 20° C
MB500 magnetic strip
Repeat accuracy
±1
 Increment(s)
Travel speed
≤5
 m/s
0.1 … 2 mm reading distance
Feature
Technical Specifications
Enhancement
Ambient temperature
0 … 70 °C
Storage temperature
-30 … 80 °C
Relative humidity
≤95
 %
condensation inadmissible
EMC
 EN 61000-6-2
interference resistance / immission
 EN 61000-6-4
emitted interference / emission
Protection category
 IP54 at the front
EN 60529
 IP67 sensor
EN 60529
Shock resistance
300 m/s2, 11 ms
EN 60068-2-27
Vibration resistance
200 m/s2, 50 … 2 kHz
EN 60068-2-6
More information
pin assignment
With common cable for interface and battery
Signal |
Color E1 |
GND |
black |
10 … 24 V DC/8 mA |
brown |
1.5 V DC (supply backup) |
red |
Data GND (RS485 interface) |
orange |
Data B (RS485-DÜB interface) |
yellow |
Data A (RS485-DÜA interface) |
green |
With separate cable for interface and battery
Signal |
E1 |
Battery cable |
10 … 24 V DC/8 mA |
brown |
|
Data GND |
orange/black |
|
Data B |
yellow |
|
Data A |
green |
|
GND |
black |
|
1.5 V DC |
red |
Hint for mounting
A, Sensor/tape reading distance |
≤2 mm |
B, Lateral offset |
±2 mm |
C, Alignment error |
±3° |
D, Longitudinal inclination |
±1° |
E, Lateral inclination |
±3° |
Note
The connection must not be changed(e.g., different cable, cable length …)
Symbolic representation
System components
Purchase order
Product configuration
Feature
Select specifications
Enhancement
Select your specifications:
sensor cable length
0.3
0.3
2.0 m, in intervals of 0.1 m
data/
network cable length
0.1
0.1
2.0 m, in intervals of 0.1 m
battery cable length
0.2
0.2
2.0 m, in intervals of 0.1 m
interface/
protocol
S3/00
Software
S
battery holder
MB
included in the delivery
Scope of delivery
- MA501
- Fastening set
- Installation Instructions
- Distance gage
- User information
- Sensor fastening set