Profile SGH25:

  • Measuring range 0 … 2500 mm (98.42 inches)
  • Absolute measuring system
  • Pressure-resistant up to 350 bar, pressure peaks up to 450 bar
  • High degree of flexibility, adjustable to all measuring lengths thanks to teach-in 
  • Redundant interfaces available
  • Safety version usable up to Perfomace Level d
  • Analog, CANopen, SAE J1939, CANopen Safety interfaces

Add to leaflet
Mechanical data
FeatureTechnical dataAdditional information
Flangealuminum

sealing ring (PUR)

Housing

synthetic

POM

Wire designø0.45 mm steel rope (stainless)
Extension force≥3.9 N
Acceleration≤24 m/s2
Weight~0.35 kg
Electrical data
Analog interface
FeatureTechnical dataAdditional information
Operating voltage9 … 32 V DC with output 0 ... 5 V, 0.5 ... 4.5 V, 0.25 ... 4.75 V, 1.0 ... 4.9 V, reverse polarity protected
12 … 32 V DC with output 0 … 10 V, reverse polarity protected
12 … 32 V DC

with output 0 ... 20 mA, 4 ... 20 mA, but UB > Uload + 2.0 V, reverse polarity protected

24 V DC ±20 % Industrie Hydraulik, nur bei CE, verpolsicher
Current consumption<40 mA without load
<80 mA bei 12 V DC je Geber
Power input<1 W

without load

Digital inputs2 limit inputs
4 Limit Eingänge (redundant)
Input signal level high>8.4 V
Input signal level low<2.8 V
Output voltage0 … 10 V load current <10 mA
0 … 5 V load current <10 mA
0.5 … 4.75 V load current <10 mA
0.25 … 4.75 V load current <10 mA
1 … 4.9 V load current <10 mA
Output current0 … 20 mA load ≤500 Ω
4 … 20 mA

load ≤500 Ω

Linearity tolerance±0.25 % 1000 mm measurement length
Settling time<150 ms
Type of connectionplug connection system KV1H accessory
CANopen interface
FeatureTechnical dataAdditional information
Operating voltage10 … 32 V DC reverse polarity protected
24 V DC ±20 % Industrie Hydraulik, nur bei CE, verpolsicher
Current consumption<40 mA bei 24 V DC
<80 mA bei 12 V DC
Power input<1 W
Linearity tolerance±0.25 % 2500 mm Messlänge
Interface

according to ISO 1189, not isolated

CANopen, CIA 406, CIA 301, CIA 305
Addressadjustable per SDO or Layer Setting Service (LSS)
Baud rate20 kBit/s
50 kBit/s
125 kBit/s
250 kBit/s
500 kBit/s
800 kBit/s
1 MBit/s
Cycle time<1.5 ms
Starting time<150 ms
Type of connectionplug connection system KV1H accessory
Schnittstelle CANopen Safety
FeatureTechnical dataAdditional information
Operating voltage9 … 32 V DC verpolsicher
24 V ±20% Industrie Hydraulik, nur bei CE, verpolsicher
Current consumption<40 mA bei 24 V DC
<80 mA bei 12 V DC
Power input<1 W
Linearity tolerance±0.25 % 2500 mm Messlänge
Interfacegemäß ISO 11898, nicht getrennt CANopen, CIA 406, CIA 301, CIA 305
Addresseinstellbar per SDO oder Layer Setting Service (LSS)
Baud rate20 kBit/s
50 kBit/s
125 kBit/s
250 kBit/s
500 kBit/s
800 kBit/s
1 MBit/s
Cycle time<1.5 ms
Starting time<150 ms
Type of connectionSteckverbindungssystem Zubehör KV1H
System data
FeatureTechnical dataAdditional information
Scanning

magnetic

Resolution12 Bit

analog output

0.1 mm CANopen, SAE J1939, CANopen Safety
Repeat accuracy ±0.15 mm unidirektional
Measuring range0 … 2500 mm measuring range flexibly usable between 0...2500 mm Messbereich flexibel nutzbar zwischen 0 … 2500 mm
Travel speed≤2 m/s
Failure rate290 year(s)

analog output, at 60 °C (MTBF)
EN/IEC61709 (SN29500)

240 year(s)

CANopen, at 60 °C (MTBF)
EN/IEC61709 (SN29500)

540 year(s) Analog nicht redundant, bei 40 °C (MTBF) EN/IEC61709 (SN29500)
460 year(s) CAN nicht redundant, bei 40 °C (MTBF) EN/IEC61709 (SN29500)
170 year(s) CAN Safety redundant, bei 40 °C (MTBF) EN/IEC61709 (SN29500)
Ambient conditions
FeatureTechnical dataAdditional information
Ambient temperature-40 … 105 °C

electronics

-30 … 105 °C

mechanics

Storage temperature-40 … 85 °C
Relative humidity100 % condensation admissible in the mounted and plugged condition
Operating pressure<350 bar
Overload pressure<450 bar
EMCEN 61326-1

immunity requirement of industry, class B emission limit

Protection categoryIP67 EN 60529, verbaut mit KV1H und geeignetem Gegenstecker

IP69K

built in the cylinder (IP69K), with KV1H and suitable mating connector

Wire-actuated encoder SGH25
Ordering table
Feature Order data Specifications Additional information
Measuring range
A...
1500, 2000, 2500 in mm
 
Ambient conditions
BMH
Mobil Hydraulik
CE
Industrie Hydraulik
 
Interface
C0/5V
0 … 5 VSpannungsausgang
0/10V
0 … 10 VSpannungsausgang
0.25/4.75V
0.25 … 4.75 VSpannungsausgang
0.5/4.5V
0.5 … 4.5 VSpannungsausgang
1.0/4.9V
1.0 … 4.9 VSpannungsausgang
0/20mA
0 … 20 mAStromausgang
4/20mA
4 … 20 mAStromausgang
CAN
CANopen
CANs
CANopen Safety
 
Redundant
DNR
nicht redundant
R
redundant
 