Signal | 4-core | 5-core | 6-core | 8-core | PIN |
---|---|---|---|---|---|
A | red | red | red | red | 2 |
B | orange | orange | orange | orange | 3 |
I, R | blue | blue | 6 | ||
+UB | brown | brown | brown | brown | 8 |
GND | black | black | black | black | 1 |
/A | yellow | yellow | 4 | ||
/B | green | green | 5 | ||
/I, /R | violet | 7 |
Headquarters: SIKO GmbH Weihermattenweg 2 79256 Buchenbach Germany Phone+49 7661 394-0 info@siko-global.com
Subsidiary: SIKO Products Inc. 2155 Bishop Circle E Dexter, MI 48130 USA Phone+1 (734) 426-3476 sales.us@siko-global.com
Voltage drop should be envisaged with increasing cable length. This should be taken into account for the electrical design.