Headquarters: SIKO GmbH Weihermattenweg 2 79256 Buchenbach Germany Phone+49 7661 394-0

Subsidiary: SIKO Products Asia Pte Ltd 19A, St. Michael's Road #06-05 Singapore 328003 Singapore Phone+65 62979733

Magnetic sensor MSK1000

Incremental, digital interface, resolution 0.2 μm

Profile MSK1000:

  • Max. resolution 0.2 μm
  • Repeat accuracy ±1 μm
  • Status LED display
  • Reading distance ≤0.4 mm
  • Robust metal housing

Add to leaflet
Mechanical data
FeatureTechnical dataAdditional information
Housingzinc  die-cast / aluminum  M design: aluminum front cover

zinc die-cast

ZM design

Sensor/band reading distance0.1 … 0.4 mm O, I reference signals
0.1 … 0.2 mm

RB reference signal

Cable sheath

PUR suitable for drag-chain use

6, 8-wire ø5-0.4 mm

Cable bending radius5x cable diameter static
7.5x cable diameter dynamic
Service life of cable>5 million cycles under the following test conditions:
travel range 4.5 m
travel  speed 3 m/s
acceleration 5 m/s2
ambient temperature 20 °C ±5 °C
Travel speed
  Travel speed Vmax [m/s]
Resolution [µm]0.20.640.320.160.08
13.201.600.800.40
26.403.201.600.80
516.008.004.002.00
Pulse interval [μs]0.250.501.002.00
Counting frequency [kHz]1000.00500.00250.00125.00
Electrical data
FeatureTechnical dataAdditional information
Operating voltage6.5 … 30 V DC

reverse polarity protected

4.75 … 6 V DC

no reverse polarity protection

Current consumption<25 mA unloaded
Output circuitLD (RS422)
Output signals

A, /A, B, /B, I, /I or R, /R

Output signal level high>2.5 V
Output signal level low<0.5 V
Pulse width of reference signal1 or 4 increment(s)
Real-time requirement

speed-proportional signal output

Type of connection

open cable end

plug connector

7/8-pole

D-Sub

9-pole

Signal pattern

Hint The logical condition of signals A and B is not defined in reference to the index signal I or the reference signal R. It can deviate from the signal form.

Hint Reference or index signal with 4 increments (360°) signal length is only valid from the 5th counting step onwards. A corresponding delay should be taken into consideration after switching on the operating voltage.

Pulse interval
System data
FeatureTechnical dataAdditional information
Resolution0.2, 1, 2, 5 µm
System accuracy±10 µm

at TU = 20 °C

Repeat accuracy ±1 µm
Measuring range
Travel speeddepending on resolution and pulse interval see table
Ambient conditions
FeatureTechnical dataAdditional information
Ambient temperature-10 … 70 °C
Storage temperature-30 … 80 °C
Relative humidity100 % condensation admissible
EMCEN 61000-6-2 interference resistance / immission
EN 61000-6-4

emitted interference / emission

Protection categoryIP67 EN 60529
Shock resistance500 m/s2, 11 ms

EN 60068-2-27

Vibration resistance100 m/s2, 5 … 150 Hz EN 60068-2-6
Magnetic sensor MSK1000
Pin assignment
Inverted without reference signal
SignalE1E6XE8X
Ared11
Borange22
nc 33
+UBbrown44
GNDblack55
/Ayellow66
/Bgreen77
nc  8
nc  9
Inverted with reference signal
SignalE1E6XE8X
Ared11
Borange22
I,Rblue33
+UBbrown44
GNDblack55
/Ayellow66
/Bgreen77
/I, /Rviolet88
nc  9
Hint for mounting

For systems with reference points on the magnetic tape please take care that sensor and strip are correctly aligned (see picture).

Reference signalO, IR
A, Sensor/tape reading distance≤0.4 mm≤0.2 mm
B, Lateral offset±2 mm±0.5 mm
C, Alignment error±3°±3°
D, Longitudinal inclination±1°±1°
E, Lateral inclination±3°±3°

MSK1000 Hint for mounting
Symbolic representation

Scope of delivery
  • MSK1000
  • Mounting instructions
  • Fastening set
Ordering table
Feature Order data Specifications Additional information
Operating voltage
A10
6.5 … 30 V DC
11
4.75 … 6 V DC
 
Design
BM
metal housing with status LEDs
ZM
metal housing without status LEDs
 
Type of connection
CE1
open cable end
E6X
bullet connector without mating connector
E8X
D-SUB 9-pole without mating connector
cable extension on request
 
Cable length
D...
1 ... 20 m, in steps of 1 m
others on request
 
Reference signal
EO
without
I
periodic indexindex signal every 1 mm
RB
fixed reference
 
Resolution
F...
0.2, 1, 2, 5
others on request
 
Pulse interval
G...
0.25, 0.5, 1.00, 2.0
others on request
 
Ordering key

MSK1000 - A - B - C - D - E - F - G

share me

Contact

Anja Wickersheim

Anja Wickersheim
Scan the code with a suitable APP to include the contact into your phone.

Download vCard

Contact

SIKO Products Asia Pte Ltd


Scan the code with a suitable APP to include the contact into your phone.

Download vCard