Signal | PIN |
---|---|
SSI data | A |
SSI data+ | B |
SSI clock | C |
SSI clock+ | D |
+24 V DC | E |
Sine | F |
RS485 DÜA | G |
RS485 DÜB | H |
GND | J |
nc | K |
Zeroing input | L |
Cosine | M |
Headquarters: SIKO GmbH Weihermattenweg 2 79256 Buchenbach Germany Phone+49 7661 394-0 [email protected]
Feature | Technical data | Additional information |
---|---|---|
Housing | aluminum natural chromated | |
Sensor/band reading distance | ≤2 mm |
Feature | Technical data | Additional information |
---|---|---|
Operating voltage | 24 V DC ±20 % | reverse polarity protected |
Current consumption | <100 mA | |
Power input | <2 VA | |
SSI clock speed input | <500 kHz | depending on the cable length |
Output signals | sine, cosine | |
Output voltage | 1 VPP (±100 mV) | |
Period length of sin/cos output | 5 mm | |
Offset voltage | 2.5 V (±100 mV) | |
Interface | SSI (RS422) | |
RS485, service interface | ||
Cycle time | <2 ms | |
Type of connection | plug connector | 12-pole, 1x pin |
Feature | Technical data | Additional information |
---|---|---|
Resolution | 10 µm | |
System accuracy | ±(0.1 + 0.03 x L) mm, L in m | at TU = 20 °C |
Repeat accuracy | ±0.01 mm | at TU = 20 °C |
Measuring range | ≤20480 mm | |
Travel speed | ≤5 m/s |
Feature | Technical data | Additional information |
---|---|---|
Ambient temperature | -20 … 60 °C | |
Storage temperature | -20 … 70 °C | |
Relative humidity | 100 % | condensation admissible |
EMC | EN 61000-6-2 | interference resistance / immission |
EN 61000-6-4 | emitted interference / emission | |
Protection category | IP65 | EN 60529, mating connector mounted |
Shock resistance | 500 m/s2, 11 ms | EN 60068-2-27 |
Vibration resistance | 100 m/s2, 5 … 150 Hz | EN 60068-2-6 |
Signal | PIN |
---|---|
SSI data | A |
SSI data+ | B |
SSI clock | C |
SSI clock+ | D |
+24 V DC | E |
Sine | F |
RS485 DÜA | G |
RS485 DÜB | H |
GND | J |
nc | K |
Zeroing input | L |
Cosine | M |
When mounting sensor and magnetic tape, please be careful to align both system components correctly. The arrow marks on the tape and sensor must point in the same direction when mounting the components.
A, Sensor/tape reading distance | ≤2 mm |
B, Lateral offset | ±1 mm |
C, Alignment error | ±1° |
D, Longitudinal tilt | ±0.5° |
E, Lateral tilt | ±3° |
additional accessories | Ordering key |
---|---|
Mating connector, 12-pole, socket | 76572 |
Mating connector, 12-pole, angle socket | 79666 |