Headquarters: SIKO GmbH Weihermattenweg 2 79256 Buchenbach Germany Phone+49 7661 394-0

Draw-Wire Encoder SGP/1

robust design with analog output and 6000 mm measurement length

Wire-actuated encoder with analog output, potentiometric, current source or voltage output, with a measuring length of up to 6000 mm. Easy adjustment of the output signal to the actual measuring length via an integrated gear mechanism.

Profile SGP/1:

  • Robust design
  • Measurement lengths up to max. 6000 mm
  • Potentiometer, voltage or power output
  • Housing made of aluminum and plastic
  • Potentiometer/resistance range adapted to actual measurement length via an integrated gear
  • Various wire types
analog

Inquire about product/Add to leaflet
Mechanical data
FeatureTechnical dataAdditional information
Housingaluminum/plastic
Wire designø0.54 mm

rustproof stainless steel

ø0.87 mm

rustproof stainless steel, plastic-coated

ø1.05 mm para-line
Extension force≥8 N
Measured distance/ rope drum revolution200 mm
Acceleration≤23.5 m/s2
Weight~0.7 kg
max. travel speed
Measuring range [mm]750100012501500175020002250250027503000325035006000
Travel speed [mm/s]≤200≤300≤300≤400≤490≤500≤600≤700≤800≤800≤900≤1000≤1000
Electrical data
Encoder potentiometer
FeatureTechnical dataAdditional information
Power rating2 W at 70 °C
Resistance1 kΩ P01
5 kΩ P05
10 kΩ P10
Resistance tolerance±5 %
Linearity tolerance±0.25 %
Transducer, power output
FeatureTechnical dataAdditional information
Operating voltage10 … 30 V DC

between I+ and I-, load ≤500 Ω

Output current4 … 20 mA
Transducer, voltage output
FeatureTechnical dataAdditional information
Operating voltage15 … 28 V DC

at 3 mA without load

Output voltage0 … 10 V DC
Resistance2 … 10 kΩ

against GND

Load≤15 mA

Measurement transducers permit optimum adjustment of the output current and output voltage to the measuring range.  The measurement transducer is pre-set at the works so that an output signal of 4 … 20 mA (MWI) or 0 … 10 V DC (MWU) is available. 

System data
FeatureTechnical dataAdditional information
Repeat accuracy ~0.5 mm

per direction of approach

Travel speed

see table

Ambient conditions
FeatureTechnical dataAdditional information
Ambient temperature-20 … 80 °C T1
-40 … 80 °C

T2 (draw-in speed ≤800 mm/s)

Protection category

IP65 (potentiometer part)

EN 60529
Draw-Wire Encoder SGP/1
Pin assignment
Potentiometric outputs P10
SignalE1 (terminal)EX (plug pin)
Po 3 1
Pe 1 2
S 2 3
nc   4
MWI transducer
SignalE1 (terminal)EX (connector pin)
I+ 1 1
I- 2 2
nc 3 3
nc   4
MWU transducer
SignalE1 (terminal)EX (connector pin)
+24 V DC 1 1
GND 2 2
Uout 3 3
nc   4
Hint for mounting

When securing the wire it must be ensured that the wire is straight and vertical in relation to the wire outlet.  Recommendation: Only select the starting position after an unwound length of approx. 5 mm. This prevents the wire hitting the end stop when it is rewound. 

SGP/1 Hint for mounting
symbolic depiction

Scope of delivery
  • SGP/1
  • Mounting instructions
Ordering table
Feature Order data Specifications Additional information
Measuring range
A...
750 ... 6000 mm, in steps of 250 mm
 
Rope fixture
BGW
wire suspension with thread
HK
wire suspension with hook
 
Wire design
CS
stainless steel ropemeasuring range ≤ 6000 mm
SK
stainless steel rope, plastic-coatedmeasuring range ≤ 4000 mm
P
para-line, non-conducting, signal colormeasuring range ≤ 2800 mm
S/FLEX
stainless steel rope, flexible rope outletmeasuring range ≤ 6000 mm
SK/FLEX
stainless steel rope, plastic-coated, flexible rope outletmeasuring range ≤ 4000 mm
 
Type of connection
DE1
cable gland PG7cable ø 3-6.5 mm
EX
for M12 connector
 
Potentiometer type
E02
10 helices/wire(P01, P05, P10)
03
10 helices/hybride(P01, P05, P10)
 
Analog output
FMWI
4 … 20 mA transducer
MWU
0 … 10 V transducer
P01
potentiometer 1 kΩ
P05
potentiometer 5 kΩ
P10
potentiometer 10 kΩ
 
Operating temperature
GT1
-20 … +80 °C
T2
-40 … +80 °C≤ feed speed 800 mm/s
 
Ordering key
SGP/1
-
A
-
B
-
C
-
D
-
E
-
F
-
G