Profile SGH50:

  • Measuring range 0 … 5000 mm (196.85 inches)
  • Absolute measuring system
  • Pressure-resistant up to 350 bar, pressure peaks up to 450 bar
  • High degree of flexibility, adjustable to all measuring lengths thanks to teach-in 
  • Redundant interfaces available
  • Safety version usable up to Performace Level d
  • Analog, CANopen, SAE J1939, CANopen Safety interfaces
SAE J1939 SAE J1939 SAE J1939 SAE J1939

Inquire about product/Add to leaflet
Mechanical data
FeatureTechnical dataAdditional information
Flangealuminum

Sealing ring (HNBR)

Housing

synthetic

PA66
Wire designø0.45 mm steel rope (stainless)
Extension force≥4 N
Acceleration≤24 m/s2
Electrical data
Analog interface
FeatureTechnical dataAdditional information
Operating voltage9 … 32 V DC Ambient condition MH,
at output 0 ... 5 V, 0.5 ... 4.5 V,
0.25 ... 4.75 V, 1.0 ... 4.9 V, reverse polarity protected
12 … 32 V DC Ambient condition MH,
at output 0 ... 10 V, reverse polarity protected
12 … 32 V DC

Ambient condition MH,
at output 0 ... 20 mA, 4 ... 20 mA,
but UB > Uload +2.0 V, reverse-polarity protected

24 V DC ±20% Ambient condition CE, reverse polarity protected
Current consumption<40 mA at 24 V DC, per encoder
<80 mA at 12 V DC, per encoder
Power input<1 W

without load, per encoder

Digital inputs4 Limit inputs (redundant)
2 Limit inputs (not redundant)
Input signal level high>8.4 V
Input signal level low<2.8 V
Output voltage0 … 10 V load current <10 mA
0 … 5 V load current <10 mA
0.5 … 4.75 V load current <10 mA
0.25 … 4.75 V load current <10 mA
1 … 4.9 V load current <10 mA
Output current0 … 20 mA load ≤500 Ω
4 … 20 mA

load ≤500 Ω

Linearity tolerance±0.25 % 5000 mm measurement length
Cycle timetypisch 1.5 ms
Starting time<150 ms
Type of connectionplug connection system KV1H accessory
CANopen interface
FeatureTechnical dataAdditional information
Operating voltage9 … 32 V DC Ambient condition MH,
reverse polarity protected
24 V DC ±20% Ambient condition CE,
reverse polarity protected
Current consumption<40 mA at 12 V DC, per encoder
<60 mA at 12 V DC, per encoder
Power input<1 W per encoder
Linearity tolerance±0.25 % 5000 mm measurement length
Interface

according to ISO 11898, not electrically isolated

CANopen, CIA 406, CIA 301, CIA 305
Addressadjustable per SDO or Layer Setting Service (LSS)
Baud rate20 kBit/s
50 kBit/s
125 kBit/s
250 kBit/s
500 kBit/s
800 kBit/s
1 MBit/s
Cycle timetypisch 1.5 ms
Starting time<150 ms
Type of connectionplug connection system KV1H accessory
CANopen Safety interface
FeatureTechnical dataAdditional information
Operating voltage9 … 32 V DC Mobil Hydraulik, verpolsicher
24 V DC ±20 % Industrie Hydraulik, verpolsicher
Current consumption<40 mA bei 24 V DC, je Geber
<80 mA bei 12 V DC, je Geber
Power input<1 W
Linearity tolerance±0.25 % 2500 mm Messlänge
InterfaceISO 11898, galvanisch nicht getrennt CANopen Safety (EN50325-5)
Addresseinstellbar per SDO oder Layer Setting Service (LSS)
Baud rate20 kBit/s
50 kBit/s
125 kBit/s
250 kBit/s
500 kBit/s
800 kBit/s
1 MBit/s
Cycle timetypisch 1.5 ms
Settling time<150 ms
Type of connectionSteckverbindungssystem Zubehör KV1H
System data
FeatureTechnical dataAdditional information
Scanning

magnetic

Resolution12 Bit

analog output

0.1 mm CANopen, SAE J1939, CANopen Safety
Measuring range0 … 5000 mm measuring range flexibly usable between 0...5000 mm Measuring range flexibly usable between 0 ... 5000 mm
Travel speed≤2 m/s
Ambient conditions
FeatureTechnical dataAdditional information
Ambient temperature-40 … 105 °C

electronics

-30 … 100 °C

mechanics

Storage temperature-40 … 85 °C
Relative humidity100 % condensation admissible in the mounted and plugged condition
Operating pressure<350 bar Pn based on ISO19879
Overload pressure<450 bar Pmax based on ISO 19879
Test pressure650 bar Pstatic based on ISO 19879
EMCEN 61326-1

Ambient condition CE, industry immunity requirement, class B emission limit

ISO 11452-1,-2,-3,-4,-5 Ambient condition MH, interference EUB
ISO 7637-1,-2 Ambient condition MH, transient impulses
ISO / TR 10605 Ambient condition MH, electrostatic discharge (ESD)
Protection categoryIP67 EN 60529, built in cylinder (IP69K) with KV1H and suitable mating connector

IP69K

ISO 26053, built in cylinder (IP69K), with KV1H and suitable mating connector

Shock resistance≤500 m/s2 , 11 ms

EN 60068-2-27, half sine, 3 axes (+/-), each 1000 shocks

≤1000 m/s2 , 11 ms EN 60068-2-27, half sine, 3 axes (+/-), each 3 shocks
Vibration resistance70 m/s2 effective, 10 ... 2000 Hz

EN 60068-2-64, noise, 3 axes, 1 hour each

Wire-actuated encoder SGH50
Scope of delivery
  • SGH50
  • Quick Start Guide
Ordering table
Feature Order data Specifications Additional information
Measuring range
A...
3000, 3500, 4000, 4500, 5000 in mm
 
Ambient conditions
BMH
mobil hydraulics
CE
industrial hydraulics
 
Interface
C0/5V
0 … 5 V
0/10V
0 … 10 V
0.25/4.75V
0.25 … 4.75 V
0.5/4.5V
0.5 … 4.5 V
1.0/4.9V
1.0 … 4.9 V
0/20mA
0 … 20 mA
4/20mA
4 … 20 mA
CAN
CANopen
CANs
CANopen Safety
 
Redundancy
DNR
not redundant
R
redundant
 
Ordering key
SGH50
-
A
-
GW6
-
B
-
C
-
D
-
M1
-
DS
-
S