Max. power supply of the power supply unit used: 100 VA. The power supply used corresponds to SELV/Limited Energy (IEC 61010-1) or SELV/LPS (IEC 60950-1) or Class 2 (UL 1310).
Display/display range
6-digit LCD 14-segment, ~8 mm height
decimal points, 2 rows, (backlit LED red/white)
Status display
2x two-color LED (red/green)
acknowledgment status, configurable
Keys
acknowledgment, parameterization
Bus connection
RS485; CANopen
no galvanic isolation
Type of connection
2x M8-plug connectors (A-coded)
4-pole, 1x socket, 1x pin
grounding via flat male tab 6.3 mm or terminal lug
Ambient conditions
Feature
Technical data
Additional information
Ambient temperature
0 … 60 °C
Storage temperature
-20 … 80 °C
Relative humidity
condensation inadmissible
EMC
EN 61000-6-2
interference resistance / immission
EN 61000-6-4
emitted interference/emission
Safety regulations
DIN EN 61010-1 (VDE 0411-1)
Limited power supply according to DIN EN 61010-1 Section 9.4. Protection class II Surge category II Pollution level 2