Measure ød [mm] | Measure L [mm] |
---|---|
6h7 | 10 |
8h7 | 15 |
10h7 | 20 |
Headquarters: SIKO GmbH Weihermattenweg 2 79256 Buchenbach Germany Phone+49 7661 394-0 info@siko-global.com
Feature | Technical data | Additional information |
---|---|---|
Shaft | stainless steel | |
Housing | die-cast | |
Speed | ≤12000 rpm | IP65 |
≤6000 rpm | IP65 continuous operation | |
≤6000 rpm | IP66/IP67 | |
≤3000 rpm | IP66/IP67 continuous operation | |
Moment of inertia | ~1.8 x 10-6 kgm2 | |
Starting torque | <0.01 Nm at 20 °C | IP65 |
<0.05 Nm at 20 °C | IP66/IP67 | |
Shaft load rating | 100 N | radial |
50 N | axial | |
Cable sheath | PVC | ∼ø6.7 mm |
Cable bending radius | 75 mm | static |
110 mm | dynamic | |
Weight | ~0.4 kg |
Measure ød [mm] | Measure L [mm] |
---|---|
6h7 | 10 |
8h7 | 15 |
10h7 | 20 |
Feature | Technical data | Additional information |
---|---|---|
Operating voltage | 10 … 30 V DC | reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310) |
Current consumption | typical 50 mA | ≤100 mA (no load) |
Output signal level high | ≥UB - 1.0 V | short-circuit proof |
Output signal level low | ≤0.5 V | short-circuit proof |
Pulse frequency | ≤300 kHz | |
Load | ±20 mA | max. adm. |
Type of connection | 1x M12 connector | 5-pole, 1x pin |
Feature | Technical data | Additional information |
---|---|---|
Operating voltage | 10 … 30 V DC | reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310) |
Current consumption | typical 50 mA | ≤100 mA (no load) |
Output signal level high | ≥UB - 1.0 V | short-circuit proof |
Output signal level low | ≤0.5 V | short-circuit proof |
Pulse frequency | ≤300 kHz | |
Load | ±20 mA | max. adm. |
Type of connection | open cable end | |
1x M23 connector | 12-pole, 1x pin |
Feature | Technical data | Additional information |
---|---|---|
Operating voltage | 5 … 30 V DC | reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310) |
Current consumption | typical 40 mA | ≤90 mA (no load) |
Output signal level high | ≥2.5 V | short-circuit proof, not against UB |
Output signal level low | ≤0.5 V | short-circuit proof, not against UB |
Pulse frequency | ≤300 kHz | |
Load | ±20 mA | max. adm. |
Type of connection | open cable end | |
1x M23 connector | 12-pole, 1x pin |
Feature | Technical data | Additional information |
---|---|---|
Approval | UL | UL 61010-1, File No. E503367 |
Feature | Technical data | Additional information |
---|---|---|
MTTFd | 60.1 year(s) |
Feature | Technical data | Additional information |
---|---|---|
Ambient temperature | -40 … 85 °C | plug |
-30 … 85 °C | static laying of cables | |
-20 … 85 °C | dynamic laying of cables | |
EMC | EN 61326-1 | immunity requirement of industry |
Safety regulations | UL 61010-1 | Indoor use, outdoor use possible, not intended for use involving direct exposure to UV light. Environment dry / wet. Protection class III as per EN 61140. Pollution degree 2 as per EN 61010. Maximum humidity 93% at 40 °C. |
Protection category | IP65, IP66/IP67 | EN 60529 (protection type not yet reviewed by UL) |
Shock resistance | 3000 m/s2, 6 ms | EN 60068-2-27 |
Vibration resistance | 300 m/s2, 10 … 2000 Hz | EN 60068-2-6 |
Signal OP, LD | Signal PP | Cable color E1 |
---|---|---|
/B | nc | pink |
+SUB (sense line) | +SUB (sense line) | red-blue |
0 | 0 | blue |
/0 | nc | red |
A | A | green |
/A | nc | yellow |
B | B | gray |
GND | GND | white |
SGND (sense line) | SGND (sense line) | gray-pink |
+UB | +UB | brown |
Signal | PIN E12 |
---|---|
GND | 1 |
+UB | 2 |
A | 3 |
B | 4 |
0 | 5 |
Signal | PIN E2 |
---|---|
/B | 1 |
+SUB (Sense line) | 2 |
0 | 3 |
/0 | 4 |
A | 5 |
/A | 6 |
nc | 7 |
B | 8 |
nc | 9 |
GND | 10 |
SGND (Sense line) | 11 |
+UB | 12 |
Feature | Order data | Specifications | Additional information |
---|---|---|---|
Pulses/revolution | A... | 50, 64, 100, 200, 250, 256, 300, 360, 400, 500, 512, 800, 1000, 1024, 1200, 2000, 2048, 2500, 3600, 4000, 600, 4096, 5000 | |
Type of connection | BE1 | open cable end | only with OP, LD |
E2 | plug M23 | only with OP, LD | |
E12 | plug M12 | only with PP | |
Position of electrical connection | CA | axial | |
R | radial | ||
Cable length | D... | 01.0, 02.0, 03.0, 04.0, 05.0, 06.0, 08.0, 10.0, 15.0, 20.0 in m | only with E1 |
OK | only with E2 and E12 | ||
Mounting type | EM1 | clamping flange | |
M2 | servo flange | ||
Output circuit | FPP | push-pull | |
OP | push-pull with inversion | ||
LD | LineDriver | ||
Shaft diameter x length | G6x10 | ø6 mm, length 10 mm | |
8x15 | ø8 mm, length 15 mm | ||
10x20 | ø10 mm, length 20 mm | ||
Protection category | HIP65 | IP65 | |
IP66/67 | IP66/IP67 | ||
additional accessories | Ordering key |
---|---|
Mating connector, with PP, 5-pole, socket | 84109 |