Signal | E1 | E6X |
---|---|---|
GND | black | 1 |
+UB | brown | 2 |
A | red | 3 |
B | orange | 4 |
nc | 5 | |
nc | 6 | |
nc | 7 |
Headquarters: SIKO GmbH Weihermattenweg 2 79256 Buchenbach Germany Phone+49 7661 394-0 [email protected]
Compact sensor, incremental, digital interface, reading distance 20 mm
Reading distance ≤20 mm
Feature | Technical data | Additional information |
---|---|---|
Housing | plastic ABS gray | |
Sensor/band reading distance | 5 … 20 mm | |
Cable sheath | PUR, suitable for drag-chain use | 4-wire ø4.4-0.4 mm; 6, 8-wire ø5-0.4 mm |
Cable bending radius | 5x cable diameter | static |
7.5x cable diameter | dynamic | |
Service life of cable | >5 million cycles | under the following test conditions: travel range 4.5 m travel speed 3 m/s acceleration 5 m/s2 ambient temperature 20 °C ±5 °C |
Feature | Technical data | Additional information |
---|---|---|
Operating voltage | 24 V DC ±20 % | reverse polarity protected |
5 V DC ±5 % | no reverse polarity protection | |
Current consumption | <50 mA | PP, unloaded |
<25 mA | LD | |
Output circuit | PP, LD (RS422), TTL | |
Output signals | A, A/, B, B/, I, I/ | 90° off-phase |
Output signal level high | UB - 2.5 V | PP |
RS422 specific | LD | |
>2.4 V | TTL | |
Output signal level low | <0.8 V | PP |
RS422 specific | LD | |
<0.4 V | TTL | |
Latency | 1.5 µs | |
Pulse width of reference signal | 1 increment(s) | |
Real-time requirement | speed-proportional signal output | |
Type of connection | open cable end | |
plug connector | 7/8-pole |
Feature | Technical data | Additional information |
---|---|---|
Resolution | 0.25, 0.5, 1, 2 mm | |
System accuracy | ±2 mm | at TU = 20 °C, length-dependent error depends on the mounting situation |
Repeat accuracy | ±2 increment(s) | |
Measuring range | ∞ | |
Travel speed | ≤15 m/s |
Feature | Technical data | Additional information |
---|---|---|
Ambient temperature | -10 … 70 °C | |
Storage temperature | -30 … 80 °C | |
Relative humidity | 100 % | condensation admissible |
EMC | EN 61000-6-2 | interference resistance / immission |
EN 61000-6-4 | emitted interference / emission | |
Protection category | IP67 | EN 60529 |
Shock resistance | 500 m/s2, 11 ms | EN 60068-2-27 |
Vibration resistance | 100 m/s2, 5 … 150 Hz | EN 60068-2-6 |
Signal | E1 | E6X |
---|---|---|
GND | black | 1 |
+UB | brown | 2 |
A | red | 3 |
B | orange | 4 |
nc | 5 | |
nc | 6 | |
nc | 7 |
Signal | E1 | E6X |
---|---|---|
A | red | 1 |
B | orange | 2 |
I | blue | 3 |
+UB | brown | 4 |
GND | black | 5 |
/A | yellow | 6 |
/B | green | 7 |
/I | violet | 8 |
Signal | E1 | E6X |
---|---|---|
A | red | 1 |
B | orange | 2 |
nc | 3 | |
+UB | brown | 4 |
GND | black | 5 |
/A | yellow | 6 |
/B | green | 7 |
Feature | Order data | Specifications | Additional information |
---|---|---|---|
Operating voltage | A4 | 10 … 30 V DC | |
5 | 5 V DC | A voltage drop is to be expected with increasing cable length. This must be taken into account in the electrical design. | |
Type of connection | BE1 | open cable ends | |
E6X | round connector without mating connector | ||
cable extension on request | |||
Cable length | C... | 01.0 ... 20 m, in intervals of 0.1 m | |
others on request | |||
Output circuit | DPP | push-Pull | only with operating voltage 4 |
LD | Line Driver | only with I output signal | |
TTL | TTL | only with NI output signal | |
Output signal | ENI | not inverted | |
I | inverted | not with TTL output circuit | |
Reference signal | FO | without | |
I | periodic index | only with I output signal | |
Resolution | G... | 0.25, 0.5, 1, 2 in mm | |