Magnetic sensor MSA213K
high-resolution absolute, numerous interfaces, swivel-mounted plug
- High absolute resolution 1 μm
- Repeat accuracy max. ±1 μm
- Reading distance ≤0.8 mm
- Measuring range 0 … 16 m
- Function and status display LED
- Interface BiSS C, SSI, IO-Link
- Optionally analog Sin/Cos 1 Vss or digital line driver
- Connection technology M12 (A-coded), swivel-mounted
- Industry 4.0 ready
Technical drawing
Technical Specifications
Signal pattern, Sin/Cos output
F: 1 VSS ±10 %
M: 90° ±1.0° / ±3° (25 kHz)
Signal pattern, LD output circuit
Pulse interval, LD output circuit
Travel speed
Travel speed Vmax [m/s] |
|||||||
Resolution [µm] |
1 |
10.00 |
5.00 |
2.00 |
1.00 |
0.50 |
0.20 |
5 |
25.00 |
25.00 |
10.00 |
5.00 |
2.50 |
1.00 |
|
10 |
25.00 |
25.00 |
20.00 |
10.00 |
5.00 |
2.00 |
|
Pulse interval [μs] |
0.10 |
0.20 |
0.50 |
1.00 |
2.00 |
5.00 |
|
Counting frequency [kHz] |
2500.00 |
1250.00 |
500.00 |
250.00 |
125.00 |
50.00 |
|
3 |
1 |
2 |
2 |
2 |
2 |
2 |
2 |
More information
pin assignment
SSI, BiSS C interface without LD, 1 Vss
SSI |
BiSS C |
PIN |
nc |
nc |
1 |
D+ |
SLO |
2 |
D- |
NSLO |
3 |
T- |
NMA |
4 |
+UB |
+UB |
5 |
nc |
nc |
6 |
nc |
nc |
7 |
nc |
nc |
8 |
nc |
nc |
9 |
nc |
nc |
10 |
T+ |
MA |
11 |
GND |
GND |
12 |
SSI, BiSS C interface with LD, 1 Vss
SSI |
BiSS C |
PIN |
nc |
nc |
1 |
D+ |
SLO |
2 |
D- |
NSLO |
3 |
T- |
NMA |
4 |
+UB |
+UB |
5 |
/A, Sin- |
/A, Sin- |
6 |
A, Sin+ |
A, Sin+ |
7 |
/B, Cos- |
/B, Cos- |
8 |
B, Cos+ |
B, Cos+ |
9 |
nc |
nc |
10 |
T+ |
MA |
11 |
GND |
GND |
12 |
IO-Link interface without LD, 1 Vss
Signal |
PIN |
L+ (+UB) |
1 |
I/Q |
2 |
L- (GND) |
3 |
C/Q |
4 |
IO-Link interface with LD, 1 Vss
Signal |
PIN |
nc |
1 |
nc |
2 |
nc |
3 |
nc |
4 |
L+ (+UB) |
5 |
/A, Sin- |
6 |
A, Sin+ |
7 |
/B, Cos- |
8 |
B, Cos+ |
9 |
C/Q |
10 |
I/Q |
11 |
L- (GND) |
12 |
Industry 4.0
Process data |
Smart Value |
Smart Function |
Actual position |
-- |
Plausibility monitoring |
Hint for mounting
A, Sensor/tape reading distance |
≤0.8 mm |
B, Lateral offset |
±0.6 mm |
C, Alignment error |
±1° |
D, Longitudinal inclination |
max. sensor/tape A reading distance must never be exceeded. |
E, Lateral inclination |
max. sensor/tape A reading distance must never be exceeded. |
System components
Purchase order
Product configuration
Feature
Select specifications
Enhancement
incremental resolution
1
Pulse interval
0.1
Accessories
Scope of delivery
- MSA213K
- Distance gage
- Quick Start Guide