Magnetic sensor MSK5000
Incremental, digital interface, resolution 1 μm, scaling factor 1250
- max. resolution 1 μm
- Repeat accuracy ±0.01 mm
- Repeat accuracy ±1 increment
- LED status display
- Works with magnetic tape MB500/1, magnetic ring MR500, magnetic band ring MBR500
- Reading distance ≤2 mm
- max. 200000 pulses/revolution in conjunction with MR500 or MBR500 (160 poles)
- optionally with reference point R or flexible reference marks FR
Technical drawing
Technical Specifications
Travel/circumferential speed
Travel/circumferential speed Vmax [m/s] |
|||||||||||
Resolution/ Scaling factor |
0.001/1250 |
4.00 |
3.20 |
1.60 |
0.80 |
0.32 |
0.20 |
0.10 |
0.05 |
0.03 |
0.01 |
0.005/250 |
20.00 |
16.00 |
8.00 |
4.00 |
1.60 |
1.00 |
0.50 |
0.25 |
0.13 |
0.06 |
|
0.01/125 |
25.00 |
25.00 |
16.00 |
8.00 |
3.20 |
2.00 |
1.00 |
0.50 |
0.25 |
0.12 |
|
0.025/50 |
25.00 |
25.00 |
25.00 |
20.00 |
8.00 |
5.00 |
2.50 |
1.25 |
0.63 |
0.30 |
|
0.05/25 |
25.00 |
25.00 |
25.00 |
25.00 |
16.00 |
10.00 |
5.00 |
2.50 |
1.25 |
0.61 |
|
0.1/12.5 |
25.00 |
25.00 |
25.00 |
25.00 |
25.00 |
20.00 |
10.00 |
5.00 |
2.50 |
1.21 |
|
Pulse interval [μs] |
0.20 |
0.25 |
0.50 |
1.00 |
2.50 |
4.00 |
8.00 |
16.00 |
32.00 |
66.00 |
|
Counting frequency [kHz] |
1250.00 |
1000.00 |
500.00 |
250.00 |
100.00 |
62.50 |
31.25 |
15.63 |
7.81 |
3.79 |
|
9 |
2 |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
1 |
Signal image
Note
The logical condition of signals A and B is not defined in reference to the index signal I or the reference signal R. It can deviate from the signal form.
Note
Reference or index signal with 4 increments (360°) signal length is only valid from the 5th counting step onwards. A corresponding delay should be taken into consideration after switching on the operating voltage.
Pulse interval, LD output circuit
More information
pin assignment
Inverted without reference signal
Signal |
E1 |
E6X |
E8X |
A |
red |
1 |
1 |
B |
orange |
2 |
2 |
nc |
3 |
3 |
|
+UB |
brown |
4 |
4 |
GND |
black |
5 |
5 |
/A |
yellow |
6 |
6 |
/B |
green |
7 |
7 |
nc |
8 |
||
nc |
9 |
Inverted with reference signal
Signal |
E1 |
E6X |
E8X |
A |
red |
1 |
1 |
B |
orange |
2 |
2 |
I,R |
blue |
3 |
3 |
+UB |
brown |
4 |
4 |
GND |
black |
5 |
5 |
/A |
yellow |
6 |
6 |
/B |
green |
7 |
7 |
/I, /R |
violet |
8 |
8 |
nc |
9 |
Hint for mounting
Reference signal |
O, I |
R |
FR |
A, Sensor/tape reading distance |
≤2 mm |
≤1.5 mm |
0.4 … 1.0 mm |
B, Lateral offset |
±2 mm |
±0.5 mm |
±0.5 mm |
C, Alignment error |
±3° |
±3° |
±3° |
D, Longitudinal inclination |
±1° |
±1° |
±1° |
E, Lateral inclination |
±3° |
±3° |
±3° |
2 |
1 |
1 |
1 |
Purchase order
Product configuration
Feature
Select specifications
Enhancement
Operating voltage
10
design
K
Type of connection
E1
Cable length
01.0
Output circuit
PP
reference signal
O
linear resolution/
radial scaling factor
0.001/1250
Pulse interval
0.2
Accessories
Comparable products
Scope of delivery
- MSK5000
- Fastening set
- Installation Instructions